Download Navigation
 
Home | Support | Tech Notes | 2408mkII analog inputs can operate at plus 4db or minus 10db
Document Actions

2408mkII analog inputs can operate at plus 4db or minus 10db

The analog inputs on the 2408mkII ship at a default of +4db. You can easily switch the inputs on the 2408mkII to -10db, if desired. Disconnect the power cable from the 2408 mkII and remove it’s cover. Be sure to get all of the screws. Three on the front, two in the back, and two on either side. When you remove the cover you will see 8 small plastic jumpers that are in line with the 1/4 connectors.When one pin is covered with the jumper the inputs are operating at +4db.When both pins are covered the inputs are operating at -10db.If you would like to set any of your analog inputs to -10db, simply cover both pins with the plastic jumper.